nport-5650-8-moxa-rackmount-serial-device-servers.png

 

• Ethernet Interface
Number of Ports 1
Speed 10/100 Mbps, auto MDI/MDIX
Connector 8-pin RJ45
Magnetic Isolation Protection 1.5 kV built-in
• Optical Fiber Interface (for -M-SC and -S-SC)

table

 

 
• Serial Interface
Number of Ports 8 or 16
Serial Standards NPort 5610: RS-232
NPort 5630: RS-422/485
NPort 5650: RS-232/422/485
Connector RJ45 (8 pins)
RS-485 Data Direction Control ADDC® (Automatic Data Direction Control)
Pull High/Low Resistor for RS-485 1 kΩ, 150 kΩ (NPort 5650-8/16)
• Serial Communication Parameters
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control DSR/DTR and RTS/CTS (RS-232 only), XON/XOFF
Baudrate Supports standard baudrates (unit=bps):50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k
• Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
• Software
Network Protocols ICMP, IPv4, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP V1, HTTP, SMTP, SNTP, ARP, PPP, SLIP, RTelnet, RFC2217
Configuration Options Web Console, Telnet Console, Windows Utility
Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY Drivers SCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Linux Real TTY Drivers Linux 2.4.x, 2.6.x, 3.x, 4.x
Android API Android 3.1.x and later
NPort 5150AI-M12 1-port RS-232/422/485 device server with M12 connector, M12 power input, -25 to 55°C operating temperature
NPort 5150AI-M12-CT 1-port RS-232/422/485 device server with M12 connector, M12 power input, -25 to 55°C operating temperature, conformal coating
NPort 5150AI-M12-T 1-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -40 to 75°C operating temperature
NPort 5150AI-M12-CT-T 1-port RS-232/422/485 device server with M12 connector, M12 power input, conformal coating, -40 to 75°C operating temperature
NPort 5250AI-M12 2-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -25 to 55°C operating temperature
NPort 5250AI-M12-CT 2-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -25 to 55°C operating temperature, conformal coating
NPort 5250AI-M12-T 2-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -40 to 75°C operating temperature
NPort 5250AI-M12-CT-T 2-port RS-232/422/485 device server with M12 connector, M12 power input, conformal coating, -40 to 75°C operating temperature
NPort 5450AI-M12 4-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -25 to 55°C operating temperature
NPort 5450AI-M12-CT 4-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -25 to 55°C operating temperature, conformal coating
NPort 5450AI-M12-T 4-port RS-232/422/485 device server, 1 10/100BaseT(X)port with M12 connector, M12 power input, -40 to 75°C operating temperature
NPort 5450AI-M12-CT-T 4-port RS-232/422/485 device server with M12 connector, M12 power input, conformal coating, -40 to 75°C operating temperature
   
DR-75-48 75W/1.6A DIN-Rail 48 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-48 120W/2.5A DIN-Rail 48 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC, -10 to 60°C operating temperature
DK-TN-5308 DIN Rail Mount Kit, 1 pcs of plates (174x60x12.8mm), 3 screws (PMS M3X30mm), 3 screws (PMS M3X4mm)
Mini DB9F-to-TB DB9 Female to Terminal Block connector
   
NPort IAW5150A-6I/O 1-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
NPort IAW5250A-6I/O 2-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
WK-51-01 Wall-mounting kit, 51mm wide
   
NPort S8455I 4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, 0 to 60°C operating temperature
NPort S8455I-T 4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, -40 to 75°C operating temperature
NPort S8455I-MM-SC 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-SS-SC 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-MM-SC-T 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8455I-SS-SC-T 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8458-4S-SC-T 4 RS-232/422/485 ports, 4 10/100M Ethernet ports, 4 100M single-mode fiber ports with SC connector, 12-48 VDC, -40 to 85°C operating temperature
   
PWR-12125-WPEU-S1 Non-locking barrel plug, 12VDC 1.25A, 100-240VAC with Continental European (EU) Plug, 0 to 40°C
PWR-12125-WPUSJP-S1 Non-locking barrel plug, 12VDC 1.25A, 100-240VAC with US/JP Plug, 0 to 40°C
PWR-12125-WPUK-S1 Non-locking barrel plug, 12VDC 1.25A, 100-240VAC with United Kingdom (UK) Plug, 0 to 40°C
PWR-12125-WPAU-S1 Non-locking barrel plug, 12VDC 1.25A, 100-240VAC with Australian (AU) Plug, 0 to 40°C
PWR-12125-WPCN-S1 Non-locking barrel plug, 12VDC 1.25A, 100-240VAC with China (CN) Plug, 0 to 40°C
   
NPort 5110A 1-port RS-232 device server, 0 to 60°C operating temperature
NPort 5110A-T 1-port RS-232 device server, -40 to 75°C operating temperature
NPort 5130A 1-port RS-422/485 device server, 0 to 60°C operating temperature
NPort 5130A-T 1-port RS-422/485 device server, -40 to 75°C operating temperature
NPort 5150A 1-port RS-232/422/485 device server, 0 to 60°C operating temperature
NPort 5150A-T 1-port RS-232/422/485 device server, -40 to 75°C operating temperature
DK35A DIN-Rail Mounting Kit (35 mm)
   
PWR-12150-USJP-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, US/JP plug
PWR-12150-EU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, EU plug
PWR-12150-UK-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, UK plug
PWR-12150-CN-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, CN Plug
PWR-12150-AU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, AU plug
CBL-PJ21NOPEN-BK-30 Locking barrel plug to bare wires cable
PWR-12050-WPEU-S1 Locking barrel plug, 12VDC 0.5A, 100-240VAC with Continental European (EU) Plug, 0 to 40°C
PWR-12050-WPUSJP-S1 Locking barrel plug, 12VDC 0.5A, 100-240VAC with US/JP Plug, 0 to 40°C
PWR-12050-WPUK-S1 Locking barrel plug, 12VDC 0.5A, 100-240VAC with United Kingdom (UK) Plug, 0 to 40°C
PWR-12050-WPCN-S1 Locking barrel plug, 12VDC 0.5A, 100-240VAC with China (CN) Plug, 0 to 40°C
PWR-12050-WPAU-S1 Locking barrel plug, 12VDC 0.5A, 100-240VAC with Australian (AU) Plug, 0 to 40°C
   
NPort 5110 1-port RS-232 device server, 0 to 55°C operating temperature
NPort 5110-T 1-port RS-232 device server, -40 to 75°C operating temperature
NPort 5130 1-port RS-422/485 device server, 0 to 55°C operating temperature
NPort 5150 1-port RS-232/422/485 device server, 0 to 55°C operating temperature
   
PWR-12150-USJP-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, US/JP plug
PWR-12150-EU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, EU plug
PWR-12150-UK-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, UK plug
PWR-12150-CN-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, CN Plug
PWR-12150-AU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, AU plug
PWR-12050-WPCN-S2 Non-locking barrel plug, 12VDC 0.5A, 100-240VAC with China (CN) Plug, 0 to 40°C
PWR-12050-WPAU-S2 Non-locking barrel plug, 12VDC 0.5A, 100-240VAC with Australian (AU) Plug, 0 to 40°C
PWR-12050-WPUK-S2 Non-locking barrel plug, 12VDC 0.5A, 100-240VAC with United Kingdom (UK) Plug, 0 to 40°C
PWR-12050-WPEU-S2 Non-locking barrel plug, 12VDC 0.5A, 100-240VAC with Continental European (EU) Plug, 0 to 40°C
PWR-12050-WPUSJP-S2 Non-locking barrel plug, 12VDC 0.5A, 100-240VAC with US/JP Plug, 0 to 40°C
   
NPort P5150A 1-port RS-232/422/485 PoE device server, 0 to 60°C operating temperature
NPort P5150A-T 1-port RS-232/422/485 PoE device server, -40 to 75°C operating temperature
   
DE-211 1-port RS-232/422/485 device server with 10 Mbps Ethernet connection
TB-M9 DB9 male DIN rail wiring terminal
NP21103 DB25 terminal block kit for RS-422/485
NP21102 Male DB25 to male DB9 RS-232 cable; 30 cm
NP21101 DB25(M) to DB9(F) RS-232 Cable, 30 cm
   
NPort 5210A 2-port RS-232 device server, 0 to 60°C operating temperature
NPort 5210A-T 2-port RS-232 device server, -40 to 75°C operating temperature
NPort 5230A 2-port RS-422/485 device server, 0 to 60°C operating temperature
NPort 5230A-T 2-port RS-422/485 device server, -40 to 75°C operating temperature
NPort 5250A 2-port RS-232/422/485 device server, 0 to 60°C operating temperature
NPort 5250A-T 2-port RS-232/422/485 device server, -40 to 75°C operating temperature
   
NPort 5210 2-port RS-232 device server, 0 to 55°C operating temperature
NPort 5210-T 2-port RS-232 device server, -40 to 75°C operating temperature
NPort 5230 2-port device server with 1 RS-232 port and 1 RS-422/485 port, 0 to 55°C operating temperature
NPort 5230-T 2-port device server with 1 RS-232 port and 1 RS-422/485 port, -40 to 75°C operating temperature
NPort 5232 2-port RS-422/485 device server, 0 to 55°C operating temperature
NPort 5232-T 2-port RS-422/485 device server, -40 to 75°C operating temperature
NPort 5232I 2-port RS-422/485 device server with 2 KV optical isolation, 0 to 55°C operating temperature
NPort 5232I-T 2-port RS-422/485 device server with 2 KV optical isolation, -40 to 75°C operating temperature
   
MDR-60-24 60W/2.5A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -20 to 70°C operating temperature
MDR-40-24 40W/1.7A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input , -20 to 70°C operating temperature
DRP-240-48 240W/5A DIN-Rail 48 VDC power supply with universal 85 to 264 VAC input or 120-370 VDC, -10~70°C operating temperature
DR-75-48 75W/1.6A DIN-Rail 48 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-48 120W/2.5A DIN-Rail 48 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC, -10 to 60°C operating temperature
DR-4524 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature
DR-75-24 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-24 120W/5A DIN-rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC , -10 to 60°C operating temperature
   
NPort 5410 4-Port RS-232 Serial Device Server
NPort 5430 4-port RS-422/485 device server
NPort 5430I 4-port RS-422/485 device server with 2 KV isolation protection
NPort 5450 4-port RS-232/422/485 device server
NPort 5450-T 4-port RS-232/422/485 device server, -40 to 75°C operating temperature (without LCM)
NPort 5450I 4-port RS-232/422/485 device server with 2 KV isolation protection
NPort 5450I-T 4-port RS-232/422/485 device server with 2KV isolation protection, -40 to 75°C operating temperature (without LCM
   
TB-F9 DB9(F) DIN-Rail Wiring Terminal
TB-M9 DB9 male DIN rail wiring terminal
TB-M25 DB25 male DIN rail wiring terminal
TB-F25 DB25(F) DIN-Rail Wiring Terminal
   
NPort 5610-8 8-port RS-232 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort 5610-8-48V 8-port RS-232 rackmount device server with RJ45 connectors and 48 VDC power input
NPort 5630-8 8-port RS-422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort 5610-16 16-port RS-232 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort 5610-16-48V 16-port RS-232 rackmount device server with RJ45 connectors and 48 VDC power input
NPort 5630-16 16-port RS-422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
   
CBL-RJ45F25-150 RJ45 to DB25 Female serial cable, 150cm length
CBL-RJ45M25-150 RJ45 to DB25 male serial cable, 150cm length
CBL-RJ45M9-150 8 pin RJ45 to male DB9 connection cable, 150cm
CBL-RJ45F9-150 RJ45 to DB9 Female serial cable, 150cm length
   
NPort 5650-8 8-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort 5650-8-M-SC 8-port RS-232/422/485 rackmount device server with multi-mode fiber (SC connector)
NPort 5650-8-S-SC 8-port RS-232/422/485 rackmount device server with single-mode fiber (SC connector)
NPort 5650-8-T 8-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input, -40 to 75°C operating temperature
NPort 5650-8-HV-T 8-port RS-232/422/485 to rackmount device server with RJ45 connectors and 88 to 300 VDC power input, -40 to 85°C operating temperature
NPort 5650-16 16-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input
NPort 5650-16-M-SC 16-port RS-232/422/485 rackmount device server with multi-mode fiber (SC connector)
NPort 5650-16-S-SC 16-port RS-232/422/485 rackmount device server with single-mode fiber (SC connector)
NPort 5650-16-T 16-port RS-232/422/485 rackmount device server with RJ45 connectors and 100-240 VAC power input, -40 to 75°C operating temperature
NPort 5650-16-HV-T 16-port RS-232/422/485 to rackmount device server with RJ45 connectors and 88 to 300 VDC power input, -40 to 85°C operating temperature
   
NPort 5610-8-DT 8-port RS-232 desktop device server with DB9 male connectors and 48 VDC power input
NPort 5610-8-DT-J 8-port RS-232 desktop device server with RJ45 connectors and 48 VDC power input
NPort 5650-8-DT 8-port RS-232/422/485 desktop device server with DB9 male connectors and 48 VDC power input
NPort 5650-8-DT-J 8-port RS-232/422/485 desktop device server with RJ45 connectors and 48 VDC power input
NPort 5650I-8-DT 8-port RS-232/422/485 desktop device server with DB9 male connectors, 48 VDC power input, and 2 KV optical isolation
   
NPort 5610-8-DTL 8-port RS-232 desktop device server with DB9 male connectors, 0 to 60°C operating temperature
NPort 5650-8-DTL 8-port RS-232/422/485 desktop device server with DB9 male connectors, 0 to 60°C operating temperature
NPort 5650I-8-DTL 8-port RS-232/422/485 desktop device server with DB9 male connectors and 2 KV isolation, 0 to 60°C operating temperature
NPort 5610-8-DTL-T 8-port RS-232 desktop device server with DB9 male connectors, -40 to 75°C operating temperature
NPort 5650-8-DTL-T 8-port RS-232/422/485 desktop device server with DB9 male connectors, -40 to 75°C operating temperature
NPort 5650I-8-DTL-T 8-port RS-232/422/485 desktop device server with DB9 male connectors and 2 KV isolation, -40 to 75°C operating temperature
   
NPort IAW5150A-6I/O 1-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
NPort IAW5250A-6I/O 2-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
   
NPort S9450I-WV-T 4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-HV-T 4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
   
NPort S8455I 4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, 0 to 60°C operating temperature
NPort S8455I-T 4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, -40 to 75°C operating temperature
NPort S8455I-MM-SC 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-SS-SC 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-MM-SC-T 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8455I-SS-SC-T 4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8458-4S-SC-T 4 RS-232/422/485 ports, 4 10/100M Ethernet ports, 4 100M single-mode fiber ports with SC connector, 12-48 VDC, -40 to 85°C operating temperature
   
NPort W2150A 1-port RS-232/422/485 wireless device server with 802.11a/b/g/n WLAN, antenna, 0 to 55°C operating temperature
NPort W2250A 2-port RS-232/422/485 wireless device server with 802.11a/b/g/n WLAN, antenna, 0 to 55°C operating temperature
NPort W2150A-T 1-port RS-232/422/485 wireless device server with 802.11a/b/g/n WLAN (includes US, Euro, Japan band), -40 to 75°C operating temperature
NPort W2250A-T 2-port RS-232/422/485 wireless device server with 802.11a/b/g/n WLAN (includes US, Euro, Japan band), -40 to 75°C operating temperature
   
ANT-WSB-ANF-09 2.4 GHz,omni-directional antenna, 9 dBi, N-type (female)
ANT-WSB-PNF-12 2.4GHz, Directional/Panel antenna, 12dBi, N-type (female) connector
ANT-WSB-PNF-18 2.4 GHz, panel antenna, 18 dBi, N-type (female)
ANT-WDB-ANM-0502 2.4/5 GHz, dual-band omni-directional antenna, 5/2 dBi, N-type (male)
ANT-WDB-ANF-0609 2.4/5 GHz, dual-band omni-directional antenna, 6/9 dBi, N-type (female)
ANT-WDB-PNF-1518 2.4/5 GHz, dual-band panel antenna, 15/18 dBi, N-type (female)
ANT-WDB-ANF-0407 Dual-band omni-directional antenna: 4 dB at 2.4 GHz and 7 dB at 5 GHz
ANT-WSB-AHRM-05-1.5m 2.4 GHz, omni-directional/dipole antenna, 5 dBi
ANT-WSB5-ANF-12 5 GHz, omni-directional antenna, 12 dBi, N-type (female)
ANT-WSB5-PNF-18 Directional panel antenna: 18 dBi at 5 GHz
ANT-WDB-ANM-0407 2.4/5 GHz, dual-band omni-directional antenna, 4/7 dBi, N-type (male)
   
NPort IAW5150A-6I/O 1-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
NPort IAW5250A-6I/O 2-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
   
NPort Z2150 1-port RS-232/422/485 serial to ZigBee converter with 802.15.4, 0 to 55°C operating temperature
NPort Z2150-T 1-port RS-232/422/485 serial to ZigBee converter with 802.15.4, -40 to 75°C operating temperature
   
PWR-12150-USJP-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, US/JP plug
PWR-12150-EU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, EU plug
PWR-12150-UK-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, UK plug
PWR-12150-CN-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, CN Plug
PWR-12150-AU-SA-T 12V1.5A, -40 to 75°C operating temperature, Screw type AC power jack, AU plug
   
NPort Z3150 1-port ZigBee to Ethernet gateway, 0 to 55°C operating temperature
   
NPort IA5150A 1-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature
NPort IA5150AI 1-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature, 2KV Isolation
NPort IA5150AI-T 1-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature, 2KV Isolation
NPort IA5150A-T 1-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature
NPort IA5250A 2-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature
NPort IA5250AI 2-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature, 2KV Isolation
NPort IA5250AI-T 2-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature, 2KV Isolation
NPort IA5250A-T 2-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature
NPort IA5450A 4-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature
NPort IA5450AI 4-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 0 to 60°C operating temperature, 2KV isolation protection
NPort IA5450AI-T 4-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature, 2KV isolation protection
NPort IA5450A-T 4-port RS-232/422/485 Industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, -40 to 75°C operating temperature
NPort IA5150A-IEX 1-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, 0 to 60°C operating temperature
NPort IA5150AI-IEX 1-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation, IECEx, 0 to 60°C operating temperature
NPort IA5250A-IEX 2-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, 0 to 60°C operating temperature
NPort IA5250AI-IEX 2-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation, IECEx, 0 to 60°C operating temperature
NPort IA5450A-IEX 4-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, 0 to 60°C operating temperature
NPort IA5450AI-IEX 4-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation protection, IECEx, 0 to 60°C operating temperature
NPort IA5150A-T-IEX 1-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, -40 to 75°C operating temperature
NPort IA5150AI-T-IEX 1-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation, IECEx, -40 to 75°C operating temperature
NPort IA5250A-T-IEX 2-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, -40 to 75°C operating temperature
NPort IA5250AI-T-IEX 2-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation, IECEx, -40 to 75°C operating temperature
NPort IA5450A-T-IEX 4-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, IECEx, -40 to 75°C operating temperature
NPort IA5450AI-T-IEX 4-port RS-232/422/485 industrial automation device server with serial/LAN/power surge protection, two 10/100BaseT(X) ports with single IP, 2 kV isolation protection, IECEx, -40 to 75°C operating temperature
   
NPort IA5150 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), 0 to 55°C operating temperature
NPort IA5150I 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP) and 2 KV optical isolation, 0 to 55°C operating temperature
NPort IA5150-M-SC 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors), 0 to 55°C operating temperature
NPort IA5150I-M-SC 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical isolation, 0 to 55°C operating temperature
NPort IA5150-S-SC 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors), 0 to 55°C operating temperature
NPort IA5150I-S-SC 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical isolation, 0 to 55°C operating temperature
NPort IA5150-T 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), -40 to 75°C operating temperature
NPort IA5150I-T 1-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP) and 2 KV optical isolation, -40 to 75°C operating temperature
NPort IA5150-M-SC-T 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors), -40 to 75°C operating temperature
NPort IA5150I-M-SC-T 1-port RS-232/422/485 device server with 1 100BaseF(X) multi-mode fiber port (SC connectors) and 2 KV optical isolation, -40 to 75°C operating temperature
NPort IA5150-S-SC-T 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors), -40 to 75°C operating temperature
NPort IA5150I-S-SC-T 1-port RS-232/422/485 device server with 1 100BaseF(X) single-mode fiber port (SC connectors) and 2 KV optical isolation, -40 to 75°C operating temperature
NPort IA5150-IEX 1 RS-232/422/485 port to 2 10/100BaseT(X) ports, IECEx, 0 to 55°C operating temperature
NPort IA5150I-IEX 1 RS-232/422/485 port to 2 10/100BaseT(X) ports, 2 kV isolation protection, IECEx, 0 to 55°C operating temperature
NPort IA5150-T-IEX 1 RS-232/422/485 port to 2 10/100BaseT(X) ports, IECEx, -40 to 75°C operating temperature
NPort IA5150I-T-IEX 1 RS-232/422/485 port to 2 10/100BaseT(X) ports, 2 kV isolation protection, IECEx, -40 to 75°C operating temperature
NPort IA5150-M-SC-IEX 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, SC, IECEx, 0 to 55°C operating temperature
NPort IA5150I-M-SC-IEX 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, SC, 2 kV isolation protection, IECEx, 0 to 55°C operating temperature
NPort IA5150-S-SC-IEX 1 RS-232/422/485 port to 1 100BaseF(X) single-mode port, SC, IECEx, 0 to 55°C operating temperatur
NPort IA5150I-S-SC-IEX 1 RS-232/422/485 port to 1 100BaseF(X) single-mode port, SC, 2 kV isolation protection, IECEx, 0 to 55°C operating temperature
NPort IA5150-M-SC-T-IEX 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, SC, IECEx, -40 to 75°C operating temperature
NPort IA5150I-M-SC-T-IEX 1 RS-232/422/485 port to 1 100BaseF(X) multi-mode port, SC, 2 kV isolation protection, IECEx, -40 to 75°C, IECEx operating temperature
NPort IA5150-S-SC-T-IEX 1 RS-232/422/485 port to 1 100BaseF(X) single-mode port, SC, IECEx, -40 to 75°C operating temperature
NPort IA5150I-S-SC-T-IEX 1 RS-232/422/485 port to 1 100BaseF(X) single-mode port, SC, 2 kV isolation protection, IECEx, -40 to 75°C operating temperature
NPort IA5250 2-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), 0 to 55°C operating temperat
NPort IA5250-T 2-port RS-232/422/485 device server with 2 10/100BaseT(X) ports (RJ45 connectors, single IP), -40 to 75°C operating temperature
NPort IA5250-IEX 2 RS-232/422/485 ports to 2 10/100BaseT(X) ports, IECEx, 0 to 55°C operating temperature
NPort IA5250-T-IEX 2 RS-232/422/485 ports to 2 10/100BaseT(X) ports, IECEx, -40 to 75°C operating temperature
   
NPort IAW5150A-6I/O 1-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
NPort IAW5250A-6I/O 2-port RS-232/422/485 IEEE 802.11a/b/g/n wireless device server with 4DIs and 2DOs, 0 to 60°C operating temperature
   
NPort S9450I-WV-T 4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-HV-T 4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-WV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-HV-T 4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
   
NPort 6150 1-port RS-232/422/485 to Ethernet Secure Serial Port Server
NPort 6150-T 1-port RS-232/422/485 secure device server, -40 to 75°C operating temperature
   
NPort 6250 2-port RS-232/422/485 to Ethernet Secure Device Server
NPort 6250-M-SC 2-port RS-232/422/485 to one Multi Mode Fiber Ethernet Secure Device Server
NPort 6250-S-SC 2-port RS-232/422/485 to one Single Mode Fiber Ethernet Secure Device Server
NPort 6250-T 2-port secure device server, RS-232/422/485 to Ethernet, -40 to 75°C operating temperature
NPort 6250-M-SC-T 2-port secure device server, RS-232/422/485 to multi-mode fiber (SC connector),-40 to 75°C operating temperature
NPort 6250-S-SC-T 2-port secure device server, RS-232/422/485 to single-mode fiber (SC connector),-40 to 75°C operating temperature
   
NPort 6450 4-port RS-232/422/485 to Ethernet Secure Serial Port Server
NPort 6450-T 4-port secure device server, RS-232/422/485 to Ethernet, -40 to 75°C operating temperature
   
NPort 6610-8 8-port RS-232 to Ethernet Secure Device Server, 100-240 VAC input
NPort 6610-8-48V 8-port RS-232 to Ethernet Secure Device Server, ±48 VDC input
NPort 6610-16 16-port RS-232 to Ethernet Secure Device Server, 100-240 VAC input
NPort 6610-16-48V 16-port RS-232 to Ethernet Secure Device Server, ±48 VDC input
NPort 6610-32 32-port RS-232 to Ethernet Secure Device Server, 100-240 VAC input
NPort 6610-32-48V 32-port RS-232 to Ethernet Secure Device Server, ±48 VDC input
NPort 6650-8 8-port RS-232/422/485 to Ethernet Secure Terminal Server, 100-240 VAC input
NPort 6650-8-T 8-port RS-232/422/485 to Ethernet secure terminal server, -40 to 75°C operating temperature, 100-240 VAC input
NPort 6650-8-HV-T 8-port RS-232/422/485 to Ethernet secure terminal server, 88 to 300 VDC power input, -40 to 85°C operating temperature
NPort 6650-8-48V 8-port RS-232/422/485 to Ethernet Secure Terminal Server, ±48 VDC input
NPort 6650-16 16-port RS-232/422/485 to Ethernet Secure Terminal Server, 100-240 VAC input
NPort 6650-16-48V 16-port RS-232/422/485 to Ethernet Secure Terminal Server, ±48 VDC input
NPort 6650-16-T 16-port RS-232/422/485 to Ethernet secure terminal server, -40 to 75°C operating temperature, 100-240 VAC input
NPort 6650-16-HV-T 16-port RS-232/422/485 to Ethernet secure terminal server, 88 to 300 VDC power input, -40 to 85°C operating temperature
NPort 6650-32 32-port RS-232/422/485 to Ethernet Secure Terminal Server, 100-240 VAC input
NPort 6650-32-48V 32-port RS-232/422/485 to Ethernet Secure Terminal Server, ±48 VDC input
NPort 6650-32-HV-T 32-port RS-232/422/485 to Ethernet secure terminal server, 88 to 300 VDC power input, -40 to 85°C operating temperature
   
NM-TX02 2 10/100Base TX port
NM-TX02-T 2 10/100Base TX port, -40 to 75°C operating temperature
NM-TX01 1 10/100Base TX port
NM-TX01-T 1 10/100Base TX port, -40 to 75°C operating temperature
NM-FX01-M-SC 1 100BaseFX port, multi mode, SC connector
NM-FX01-M-SC-T 1 100BaseFX port, multi mode, SC connector, -40 to 75°C operating temperature
NM-FX01-S-SC-T 1 100BaseFX port, single mode, SC connector, -40 to 75°C operating temperature
NM-FX01-S-SC 1 100BaseFX port, single mode, SC connector
NM-FX02-M-SC 2 100BaseFX ports, multi mode, SC connector
NM-FX02-M-SC-T 2 100BaseFX ports, multi mode, SC connector, -40 to 75°C operating temperature
NM-FX02-S-SC 2 100BaseFX ports, single mode, SC connector
NM-FX02-S-SC-T 2 100BaseFX ports, single mode, SC connector, -40 to 75°C operating temperature
NM-modem-T 1 PSTN modem port with RJ11 connector, -40 to 75°C operating temperature
   
N2510-16 16-port RS-232 Async Server, 100 to 240 VAC power input
CN2510-16-48V 16-port RS-232 Async Server, +/-48 VDC power input
CN2510-8 8-port RS-232 Async Server, 100 to 240 VAC power input
CN2510-8-48V 8-port RS-232 Async Server, +/-48 VDC power input
   
CN2610-8 Dual-LAN terminal server with 8 RS-232 ports
CN2610-16 Dual-LAN terminal server with 16 RS-232 ports
CN2610-8-2AC Dual-LAN, dual-AC-power terminal server with 8 RS-232 ports
CN2610-16-2AC Dual-LAN, dual-AC-power terminal server with 16 RS-232 ports
CN2650-8 Dual-LAN terminal server with 8 RS-232/422/485 ports
CN2650-16 Dual-LAN terminal server with 16 RS-232/422/485 ports
CN2650-8-2AC Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports
CN2650-16-2AC Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports
CN2650I-8 Dual-LAN terminal server with 8 RS-232/422/485 ports and 2 KV optical isolation
CN2650I-16 Dual-LAN terminal server with 16 RS-232/422/485 ports and 2 KV optical isolation
CN2650I-8-2AC Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports and 2 KV optical isolation
CN2650I-16-2AC Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports and 2 KV optical isolation
CN2650-8-2AC-T Dual-LAN, dual-AC-power terminal server with 8 RS-232/422/485 ports, -40 to 75°C operating temperature
CN2650-16-2AC-T Dual-LAN, dual-AC-power terminal server with 16 RS-232/422/485 ports, -40 to 75°C operating temperature
CN2650I-8-HV-T Dual-LAN terminal server with 8 RS-232/422/485 ports and 2 kV optical isolation, 88 to 300 VDC power input, -40 to 85°C operating temperature
CN2650I-16-HV-T Dual-LAN terminal server with 16 RS-232/422/485 ports and 2 kV optical isolation, 88 to 300 VDC power input, -40 to 85°C operating temperature