safety-sensor.png
Performance Level
d
 
Safety category (EN ISO 13849-1)
2
 
SIL CL (EN 62061)
2
 
Response time max.
1 ms
 
Approval/Conformity
CE, TÜV, cULus
 
Operating principle
non-contact (inductive)
 
Approach direction
any to sensing surface
 
Assured operating distance Sao
4 mm
 
Assured switch off distance Sar
6 mm
 
Connection
M12x1-Male, 4-pole, A-coded
 
Switching output
PNP OSSD;PNP normally closed (NC)
 
Installation
non-flush
 
Dimension
Ø 12 x 70 mm
 
Ambient temperature
-25...70 °C, for service life ≤ 10 years
10…40 °C, for service life ≤ 20 years